Энергоэффективный циркуляционный насос Raymer IP32-17-180E
Циркуляционный насос Raymer IP32-17-180E - This is a modern device, providing effective circulation of the coolant in heating and air conditioning systems. Thanks to the inverter engine and high performance, it is able to significantly reduce electricity costs, Providing stable operation of the system and a comfortable microclimate in the room.
This pump model combines advanced technologies, allowing to optimize the operation of the heating system, reduce the load on the power grid and increase the durability of the equipment. Thanks to the compact size and modern design, the pump is easily integrated into any heating and air conditioning system, and its high level of automation makes the operation process as simple as possible.
|
Raymer circulation pump IP32-17-180E
|
Основные преимущества насоса Raymer IP32-17-180E
This model has a high level of energy efficiency, which can significantly reduce heating costs.
- Built -in intellectual control unit provides optimal performance depending on the needs of the system, automatically changing the speed of engine rotation.
- The engine has a copper winding, which guarantees a long service life and high reliability. The use of ceramic shaft and rotor on permanent magnets allows you to reduce noise level, making the pump almost silent.
- The pump body is made of durable cast iron with an anti -corrosion coating, which allows the device to use even in difficult operating conditions. The pump is also equipped with a thermal insulation casing, which reduces thermal losses and increases the efficiency of work.
Thanks to intellectual speed regulation, the pump adapts to the needs of the heating system, which avoids unnecessary electricity consumption.
Functionality
- The pump has four levels of speed 180/240/280 WT and energy -saving abstract 100 Tue., which allow the user to configure the device in accordance with the needs of the system.
- Intelligent control allows the pump to work on 20% more effective compared to ordinary models, Reducing the load on the mains and extending the service life of all equipment.
- Built -in frequency converter and display allow you to control the current electricity consumption in real time, which helps users track the operation of the system and, if necessary, make adjustments.
- Also Speed regulation is available, which allows the pump to change speed depending on the heat load, Providing stable operation of the system without unnecessary temperature drops.
- Smart frequency transformation allows the pump to adapt its work to real operating conditions, Optimizing energy costs. Besides, makes supports two types of pressure difference - special and constant control, which ensures stable operation of the system regardless of its load.
- One of the important features is the function of automatic air removal, which greatly simplifies the service process and ensures uninterrupted operation of the system.
- Low noise level makes the pump ideal for installation in residential premises, Providing comfort for users.
Specifications
- Energy efficiency corresponds to the class "a", which can significantly reduce electricity costs.
- The power of the device is 280 Tue., And the maximum productivity - before 10 m³/h.
- Pump capable of lifting the coolant to a height to 17 meters, which allows you to use it in large heating systems.
- Work fluid can have a temperature up to 110 ° C, What makes the pump a universal solution for various types of heating systems.
- The device also has a compact design and Light weight 3 kg, which simplifies installation and further maintenance.
The scope of application
Насос Raymer IP32-17-180E ideal for use in warm floor systems, one -pipe and two -pipe heating. Due to its high performance and energy efficiency, it provides stable operation of the system and allows you to save electricity without loss of heating efficiency.
Instructions for the installation of a circulation pump
- Before installing the electric pump, it is necessary to check the condition of the pipeline system, make sure, such as the remains of welding, mud or other extraneous particles. The power of the pump must correspond to the frequency 50/60 Hz, The voltage should be 230 B for a single -phase network, and the permissible voltage fluctuations should be in the range of -10% to +6%.
- Installation of the pump should be carried out in a dry and well -ventilated room, To avoid moisture and water ingress, What can cause a short circuit. The installation location should be available for maintenance or replacement of the device.
- If the pump is installed outdoors, It is necessary to provide an additional protective casing to protect against atmospheric influences. In case of installation in the room, you should take care of protecting the device from direct contact with water, to avoid risk of electric shock. It is forbidden to install a pump in rooms with high humidity, In particular in bathrooms, To prevent steam or moisture from getting into the electrical components of the device.
- After the installation is completed, it is necessary to connect the device to the power source and conduct a test launch. To do this, you need to set a high speed mode (S3) And check, whether the pump is working properly.
- For the convenience of maintenance, it is recommended to install locking cranes on the input and output line, which will allow repair work or replacement of the device without the need to drain the coolant from the system.
- The power of the pump should have a reliable grounding. The grounding contact of the power plug should be correctly connected to the electric outlet. Independent replacement of the power plug is strictly prohibited.
- At the site of installation of the pump, warning safety signs should be provided, to avoid random emergency situations.
- Regularly check the condition of the electro pump insulation. The insulation resistance in the cold state should not be lower 100 yesterday (Baby).
- In case of damage to the power cable, it must be replaced with the appropriate specialized cable or use certified components.
- Liquid, used for pumping, should be clean, Without impurities, do not contain solid particles, fibers or mineral oils. It should not be corrosion, explosive or harmful for pumping equipment.
Conclusion
Циркуляционный насос Raymer IIP32-17-180E - This is modern, reliable and energy -efficient solution for heating systems, which allows you to reduce operation costs, ensure stable equipment and create comfortable conditions in your house. Thanks to intellectual functions and a high level of automation, This pump will be a great choice for any heating system.
-
Following these recommendations will ensure the longevity and efficiency of the pump.!










