Installation of the Raymer RAY-18DS1 EVI heat pump (380V) in a private house until 200 m2, Kyiv

An object: A private house, new building in. Kyiv, area up to 200 m2

In an era of increased focus on energy efficiency and sustainability, Choosing the right heating system plays a key role in creating a comfortable and economical home space. In this context, installation of a split system heat pump Raymer RAY-18DS1 EVI in a modern house in Kyiv is an example of advanced engineering and the desire to create optimal housing comfort.

The initial step was careful planning of the installation. It included an analysis of the heating requirements of a modern home and the selection of optimal equipment to meet these needs.

At the initial stage of the project it was important to identify the key requirements for a new heating system for a modern home. The main objectives were to ensure high efficiency, reliability and integration with existing heating system elements.

Equipment selection

To achieve these goals, it was chosen heat pump Raymer RAY-18DS1 EVI on 18 kW. His choice was determined by several factors:

high power: Power in 18 kW was ideal for providing sufficient heat in a large modern house.

Split system: This provided flexibility in installation and the ability to integrate with various parts of the heating system.

Basic installation steps

As part of the project, it was necessary to install a Raymer RAY-18DS1-EVI split heat pump into the new heating system of a modern house. The main task was to ensure efficient and uniform heating of the entire house, taking into account the different heating requirements on different floors and in different areas.

1. Termojet pump group

The choice of the Termojet pump group was made for the convenience of connecting the radiator heating circuit, indirect heating boiler and other circuits. Its use made it possible to effectively control the temperature in different areas of the house.

2. Solution for underfloor heating and radiators

To ensure uniform heating, it was decided to connect a heat pump to the underfloor heating system on the first floor and to radiators on the second. This required careful planning and tuning of the system to ensure optimal performance in both zones.

3. Buffer tank and indirect heating boiler

Installing a Raymer IMP Buffer Tank 100 на 100 liters and indirect heating boiler Raymer DHWP 300 l was an important part of the decision. This made it possible to provide the necessary supply of warm water and effectively distribute heat throughout the house.

4. Condensate drainage

An important part of the project was the installation of a condensate drainage system from the external pump unit. A special pan was welded to drain condensate directly into the sewer system, which guaranteed uninterrupted and safe operation of the system in any weather.

Eventually, installation heat pump Raymer RAY-18DS1-EVI turned out to be a successful project, which not only improved the heating system in the house, but also brought significant convenience and comfort to its residents.

The project demonstrates, how correctly selected and professionally installed equipment can transform living conditions, making them more comfortable and energy efficient.

Main characteristics of the air-water heat pump Raymer RAY-18DS1-EVI on 18 kW

  • power usage: The heat pump has an energy consumption of 1200 to 4420 Tue., which provides flexibility in operation and allows you to save energy during periods of lower heating demand.
  • Heating area: Recommended heating area up to 250 sq.m makes this pump ideal for large houses and buildings, providing efficient heating without the need for additional heat sources.
  • Media heating temperature: The ability to maintain media heating temperatures up to 55℃/60℃ guarantees comfortable warmth even on the coldest days.

Technological advantages Raymer RAY-18DS1 EVI:

  • Panasonic EVI compressor: Panasonic's EVI hot injection compressor ensures maximum energy efficiency, especially at low temperatures up to -30 °C, which is critical for climates with cold winters.
  • Refrigerant type: The use of R410 refrigerant improves the efficiency and environmental friendliness of the system.
  • Smart Wi-Fi Control: This feature allows you to control your heating and cooling system remotely, providing additional user convenience.
  • Automatic defrost: This feature ensures continuous and efficient operation of the system even in freezing conditions..
  • Multifunctionality: The pump is suitable for various heating systems, including heated floors, fancoils, water heaters and modern radiators.

Heat pump installation Raymer RAY-18DS1-EVI in a private house in a new building with an area 200 м² is an example of a modern and efficient approach to the heating and hot water system. This solution provides not only energy savings and comfortable living, but also contributes to improving the environmental situation.

Taking into account all the advantages, Heat pump Raymer RAY becomes the best choice for residents, seeking a combination of comfort, savings and sustainable development.

Read more reviews of Reimer heat pumps in OUR WORKS.