An object: A private house, area 230 m2
Installing a heat pump is one of the most promising solutions, allowing to significantly reduce heating and hot water costs, while minimizing the impact on the environment.
This blog covers installation heat pump Raymer RAY-18DS1-EVI in a private house with an area 230 м², which became a key step towards achieving minimal costs for electricity consumption while ensuring comfortable living conditions.
Tasks and solutions
The main objective of the project was to reduce energy costs for heating and hot water supply without compromising living comfort.
House, area 230 м², required an efficient heating system, able to maintain optimal temperature conditions during cold months.
Equipment selection
The choice of equipment was based on a comprehensive analysis of several factors:
- House insulation: Guaranteed reduction of heat loss and increased efficiency of the heating system.
- Medium temperature heat transmitter: The use of heated floors and expanded radiators ensured uniform heat distribution throughout the rooms.
- Proper dilution of water flows: Ensures optimal coolant circulation and heating system efficiency.
Based on these factors, it was selected heat pump Raymer RAY-18DS1-EVI power 18 kW (380V), which met all the power and efficiency requirements for a given home.
Additionally, a storage tank was installed on 100 liters and an indirect heating boiler for 200 liters, which made it possible to create a complete and efficient heating and hot water system.
Scope of work completed
- Preparatory stage
Before you begin installing your heat pump, careful preparation has been carried out, including:
- Audit of an existing heating system to determine possibilities for integrating new equipment.
- Technical inspection of the facility in order to determine the optimal locations for installing the external and internal heat pump units.
- Infrastructure preparation: Laying communications, preparation of the base for the outdoor unit and installation work for the installation of additional equipment (storage tank and boiler).
- Heat pump installation
Installation heat pump Raymer RAY-18DS1-EVI included several key stages:
- Installation of the outdoor unit: Selection of location, taking into account sufficient space for air exchange and minimal impact on the aesthetics of the site.
- Installation of the indoor unit: Indoor seating, where easy access for maintenance and maximum system efficiency are ensured.
- Connection to the heating and hot water system: Integration of heat pump with storage tank and boiler, as well as with a system of underfloor heating and radiators for optimal heat distribution.
- Setup and commissioning
After installation, setup and commissioning work was carried out, including:
- Setting up the control system: Connecting smart Wi-Fi control to monitor and control your heating system remotely.
- System testing: Checking all system components for correct operation and efficiency of heating and hot water supply.
- User training: Instructing home owners on how to operate the system, Recommendations for maintenance and use of operating modes to optimize energy consumption.
Benefit for the client
Energy Saving
Thanks to the installation heat pump Raymer RAY-18DS1-EVI, the client was able to significantly reduce energy costs. The system provides power consumption ranging from 2 to 4,4 kW, which is a significant saving compared to traditional heating systems.
Comfort and convenience
Smart Wi-Fi control allows the client to control the heating and hot water system remotely, adapting it to your needs and preferences, which increases the level of living comfort.
Environmental friendliness
Using a heat pump helps reduce your carbon footprint, since the system uses renewable energy sources for heating and hot water supply, making it an environmentally friendly solution.
Installation project heat pump Raymer RAY-18DS1-EVI in a private house on 230 m2 was an important step towards creating an energy-efficient and environmentally sustainable heating and hot water supply system.
The implementation of this project showed, How modern technology can transform everyday energy use in homes, making it more economical and comfortable.
Main achievements of the project:
- Significant energy savings: Installing a heat pump allowed us to reduce energy consumption for heating and hot water supply, reaching minimum levels in 2-4,4 kW.
- Increasing living comfort: The system provides stable and uniform heating throughout the house, as well as reliable hot water supply, which creates comfortable conditions for residents.
- Improving environmental sustainability: Using renewable energy to run your heat pump helps reduce your household's carbon footprint.
For homeowners, considering installing a heat pump, It is important to carefully analyze your needs and operating conditions, choose quality equipment and contact professionals to install and configure it. Regular maintenance and proper operation will ensure long-term and efficient operation of the system.
Features air-to-water heat pump, Raymer RAY-18DS1-EVI (380AT):
- power usage 1200-4420 Tue.. This range shows, that the pump is able to adapt to different heating needs, providing energy efficiency under different operating conditions.
- Recommended heating area up to 200 м². The pump power is sufficient for efficient heating of large houses, making it ideal for spacious living spaces.
- Media heating temperature 55℃/60℃. High heating temperature guarantees, that even in the coldest months the house will be warm and comfortable.
- Panasonic DC inverter compressor EVI. Twin Rotary Inverter Compressor. DC inverter technology regulates heat pump power, adapting it to current heating needs, which increases energy efficiency and reduces costs. Panasonic inverter compressor also provides high efficiency and low noise, and also contributes to the longevity of the equipment.
- Refrigerant type R410. Eco-friendly refrigerant R410 helps reduce environmental impact.
- Smart Wi-Fi Control. Allows you to control the heating system remotely, which is convenient and practical for users.
- Auto defrost function. This feature ensures trouble-free pump operation during the winter months, preventing ice formation and maintaining system efficiency.
- Thanks to Panasonic EVI, maximum energy efficiency is achieved at low temperatures down to -30°C. This feature makes the pump particularly suitable for regions with cold climates, providing efficient heating even on the coldest days.
Compared to other heat pump models, Raymer RAY-18DS1-EVI stands out due to its efficiency and reliability. It is able to operate at lower temperatures and provide stable heating even in the coldest months.
Taking into account all the advantages, Heat pump Raymer RAY becomes the best choice for residents, seeking a combination of comfort, savings and sustainable development.
Read more reviews of Reimer heat pumps in OUR WORKS.




