An object: “Corona Hall” car wash area 1000 sq.m..
Tasks and solutions:
The goal of the project was providing a reliable and cost-effective heating system for a commercial room area 1000 square meters, consisting of five floors.
The client identified two main requirements: significant reduction in heating costs and the possibility of using solar panels in the future. The decision was the choice of the air-water heat pump Raymer RAY-32DS1-EVI on 32 kW, installed on a specially made pedestal on the roof of the building. This choice ensured reliable and efficient operation of the heating and hot water system at minimal operating costs. The gas boiler remained the backup source of heating. 78 kW, and was also installed Drazice drive on 250 liters. The developed system also provides for the possibility of adding solar panels in the future., which will allow the client to further reduce heating costs and make their business more environmentally friendly.
Scope of work completed:
- Detailed study of the object: We offered the client the installation of two heat pumps to ensure maximum comfort in such a large room consisting of five floors, but the client still chose one heat pump.
- Heat pump installation: An air-to-water heat pump was installed Raymer RAY-32DS1-EVI power 32 kW on a specially made pedestal on the roof of the building. This included preparing the installation site, installation and connection of the pump to the heating and hot water system.
- Introduction of a heat pump into an existing heating system: gas boiler and radiators, which remained a backup heating source in case of lack of energy from the heat pump. But later the client reported that, that he did not use this system anymore due to the essential appraisal of the heat pump.
- Installing a hot water tank: The Drazice drive was installed on 250 liters, providing continuous hot water supply for a commercial premises.
Benefit for the client:
- Saving on heating: Installing a heat pump allowed the client to reduce heating costs by using energy from the air, which is much more economical, than using traditional heating methods.
- System reliability: A backup heating source and an installed hot water storage tank ensure continuous operation of the heating system and hot water supply, which increases reliability and comfort for the client.
- Flexibility and extensibility: The system was designed to allow for the addition of solar panels in the future, which will allow the client to further reduce energy costs and make their business more environmentally sustainable.
Main characteristics of an air-to-water heat pump Raymer RAY-32DS1-EVI 380V 32 kW:
- power usage: From 2200 to 8000 Tue., which ensures high efficiency and energy savings.
- Media heating temperature: Range from 55°C to 60°C, which allows you to achieve the desired temperature for heating and hot water.
- Working temperature range: From -30°C to +43°C, ensuring reliable operation even in extreme conditions.
- Compressor type: Panasonic EVI inverter compressor provides high efficiency and reliability.
- Freon type: R410A, which is environmentally friendly and efficient.
Peculiarities Raymer RAY-32DS1-EVI:
- Double rotary compressor with inverter control ensures power adjustment according to needs.
- Can be used for various heating and hot water systems.
- Separate design with indoor water supply system prevents water from freezing.
- Features an intelligent controller and LED display for easy operation.
- Automatic defrost function and high efficiency at low temperatures.
- Smart Wi-Fi control for remote control and monitoring.
- Easy to install and maintain.
- Operating modes: Three operating modes are provided: heating, cooling and hot water, as well as their combinations for maximum comfort and efficiency in various conditions.
Read more reviews of Reimer heat pumps in OUR WORKS