Floor standing ultra-quiet slim fan coil unit.
Opportunities: heating, cooling.
Housing material: Quality plastic. Decor.
Certification: CE, EMC, Emf, LFGB, UR, CE, EN14511 / 4, ENISO4871, CCC
Ultra-thin fan coil unit for rooms up to 45 sq.m.
|
Main functions and features of wall-floor fan coil units Raymer
- Ultra-thin design, body width total 130 mm.
- Modern design, hi-Tech production technology and elegant appearance of the case. It matches the modern interior design style.
- Using a cross flow fan, pipeline design optimization. Strong air flow at maximum operation and at the same time low noise level.
- Air guide installed with damping. Can manually adjust the flow angle.
- Hidden Intelligent LED Temperature Controller (Remote Control) with elegant appearance and easy to use.
- Cold air protection system. There is an air stop function, when the water temperature in the system is too low.
- Left-right water pipe and electric control box can be replaced on both sides. Ease of installation and reduced dependency on furniture placement.
- Side metal plate can be removed before installation, which facilitates the connection of pipes.
- Fan coil filter easily replaceable.
- 2-way and 3 way valve are optional, which can reduce installation cost.
- Can be installed on the floor, leaning on legs (included), or on a wall without legs.
Benefits of floor fan coil unit Raymer:
- The heat exchanger consists of copper pipes with aluminum fins;
- Metal case;
- Noise insulation;
- Raymer floor-mounted fan coil units are much more efficient than any type of radiator. Where you install several radiators - you can install only one fan coil unit and the effect will be much better;
- Attractive design. Decorative horizontal insert at the bottom of the fan coil unit. The raymer fancoil will also fit into a classically styled interior, and modern design;
- Modern models of motors and fans produce minimal noise during operation;
- Blinds provide volumetric distribution of air in the room. Due to the directed distribution of air flows by fan coil units, the heating of the room is more efficient, than with radiator heating.
Assembly, maintenance and management
floor mounting, little space required for installation. Fancoil maintenance does not take much time and effort, since all elements are directly accessible. During the operation of fan coil units for cooling, the resulting condensate is discharged by a special drainage pump into the sewerage system, or is displayed on the street under a slope, or drainage is removed. Also, the installation of fan coil units can be combined with radiator heating. (if it already exists).
Cost-effective and efficient use of fan coil units, when a heat pump is used as a heat source, condensation, convection, electric boilers, as this gives you the opportunity to operate the heating source in modes 30-40 degrees (floor heating operating temperature).
Raymer fan coil units quickly warm up the room due to forced air injection (fan), not natural convection.
There are cases, when you can't do without a floor fan coil (when an existing facility is effectively heated only when supplying 60-70 degrees), Do you want to install a medium temperature heat pump?, or reduce the coolant temperature, to achieve greater savings. In cold rooms, corners, there, where are the so-called "dead zones" – to help this came up with wonderful floor fan coil units.
Fancoils floor type Raymer FLP40CM - The best decision, if you want to comprehensively solve the issue of maintaining and creating a comfortable microclimate in the entire building, or in separate rooms, with minimal cost and installation time.
Technical characteristics of fan coil units | ||||||
Model | FLP-20CM | FLP-30CM | FLP-40CM | FLP-50CM | FLP-60CM | |
Source of power | 220V,50Hz,1Ph | |||||
Maximum air flow | m3 / h | 200 | 300 | 400 | 500 | 600 |
CFM | 118 | 176 | 235 | 294 | 353 | |
Minimum air flow | m3 / h | 80 | 120 | 180 | 220 | 260 |
CFM | 47 | 71 | 106 | 129 | 153 | |
Cooling capacity | Tue. | 1000 | 1900 | 2800 | 3500 | 4000 |
Btu/h | 3400 | 6500 | 9550 | 12000 | 13700 | |
Cooling capacity (1) | Tue. | 1500 | 2850 | 4200 | 5250 | 6000 |
Btu/h | 5100 | 9700 | 14300 | 17900 | 20500 | |
Heating capacity (2) | Tue. | 2000 | 3800 | 5600 | 7000 | 8000 |
Btu/h | 6800 | 12950 | 19100 | 23900 | 27300 | |
Noise level | dB(A) | 38 | 39 | 40 | 41 | 42 |
Input power | Tue. | 15 | 18 | 20 | 26 | 32 |
Water flow volume | m3 / h | 0,17 | 0,33 | 0,49 | 0,6 | 0,64 |
pressure drop | kPa | 12 | 14 | 18 | 20 | 24 |
Water pipe connection (entrance) | R1/2″ | |||||
Water pipe connection (exit) | R1/2″ | |||||
Zmeevik | Type | High efficiency copper pipe with hydrophilic aluminum coil | ||||
Max working pressure | mPa | 1,6 | ||||
Condensation pipe (diameter) | mm | ¢21 | ||||
Size without packaging (Д×Ш×В) | mm | 700×130×581 | 900×130×581 | 1100×130×581 | 1300×130×581 | 1500×130×581 |
Packing size (Д×Ш×В) | mm | 750×180×630 | 950×180×630 | 1150×180×630 | 1350×180×630 | 1550×180×630 |
Net weight | kg | 14,7 | 18,5 | 21,6 | 24 | 28 |
Gross weight | kg | 16,5 | 20,6 | 24 | 28 | 33,5 |
Features
MODEL |
FLP-40CM |
---|---|
TYPE |
2-pipe slim fan coil unit Unltra |
Air volume,m3 / h |
400 |
COOLING CAPACITY, Tue. |
2400 |
HEAT CAPACITY, Tue. |
3850 |
INPUT POWER, Tue. |
20 |
NOTE |
With LED thermostat inside, 2-pipe system, AC motor |
Power supply |
220V/1/50Hz |
SIZE, actual, mm |
1100*130*581 |
SIZE, packaged, mm. |
1150*180*630 |
VOLUME, cu. m |
0.13041 |